my account  log out
 

AAK hydraulic sequence valves replaced the Spanish factory with design, which helped Hudson test run successfully

Create: 05/01/2022
Expired Date:05/01/2023
Category: Hydraulic presses [Equipment&Machinery]
Message:Hudson is an old purchaser of LARZEP company in Spain. He cooperates with us on are some non-standard hydraulic sequence valves, and often discuss some difficult and miscellaneous problems of hydraulic sequence valves with us. In the second half of last year, their company developed a machine tool hydraulic system, which uses the hydraulic sequence valves to implement the device of positioning first and then clamping. In order to save development time, Hudson purchased directly from Spanish hydraulic sequence valve manufacturers. According to the hydraulic sequence valve drawings provided by Hudson, the factory delivered 20 hydraulic sequence valve samples in 30 days. After the test run, it was found that the positioning clamping device reacted slowly after the machine tool was started. Check the oil circuit and components of the whole hydraulic system one by one, and there is no abnormality. Their engineers speculated that there was a problem with the hydraulic sequence valves. Hudson contacted the original factory. The manufacturer fed back that the samples of hydraulic sequence valves were completely produced according to the drawings provided by LARZEP company, and the dimensional accuracy met the requirements. Their engineers tested the hydraulic sequence valves separately and there was no abnormality. Hudson's team explored for 2 days and determined that there was a problem with the design of the hydraulic sequence valves. Hudson contacted AAK because the hydraulic sequence valve problems encountered several times before were solved by AAK. According to his fault description, drawings of hydraulic sequence valve, working parameters of hydraulic system of machine tool and video of test run, AAK engineer did find the problem in the design of hydraulic sequence valve. AAK engineer's suggestion is to change the design mode of the hydraulic sequence valve to maintain a minimum "pilot pressure" in the starting circuit and "fully open" when it is higher than the set pressure.
City:Ningbo Zhejiang[CN] 
Location:
 
Nov 19 2024Hydraulic Solenoid Cartridge Valve Equivalent to HydraForce SF08-236
Nov 12 2024 Proportional Flow Control Cartridge Valve Equivalent to HydraForce PV70-307
Nov 05 2024Hydraulic Solenoid Cartridge Valve Equivalent to HydraForce SF08-228
Oct 30 2024Hydraulic Solenoid Valve Equivalent to HydraForce SV12-2110
Oct 22 2024Hydraulic Solenoid Cartridge Valve Equivalent to HydraForce SV12-3426
Oct 15 2024Solenoid Cartridge Valve Equivalent to HydraForce SV08-2029
Oct 09 2024Pilot Operated Check Valve Equivalent to HydraForce DC08-4025
Oct 08 2024Pilot Operated Relief Valve Equivalent to HydraForce RV10-2842
Sep 25 2024Piloted Directional Valve Equivalent to HydraForce PD10-4150
Sep 24 20241 year after first order was shipped, Mexican customer placed re-peat order with AAK for Cartridge Check Valve equivalent to HydraForce CV16-2076

return back

Copyright © toextrade Inc. All rights reserved. Contact us