Message: | Maximal continuous charging current 4A
Maximal continuous Discharging current 4A
Over charge detection voltage for single cell 4.25V±0.025V
Over charge detection delay time 0.5S—1.5S
Over charge release voltage for single cell 4.15V±0.05V
Over discharge detection voltage for single cell 2.50V±0.08V
Over discharge detection delay time 50mS—150mS
Over discharge release voltage for single cell 3.0±0.10V
Over current detection voltage 100±25mv
BMS Model:LWS-3S4A-093(3S)
Over current detection current 10±2A
Detection delay time 5mS—15mS
Release condition Cut load
Detection condition Exterior short circuit
Detection delay time 200-500us
Release condition Cut load
Protection circuitry(MOSFET) ≤50mΩ
Operating Temperature Range -40~+85℃
Storage Temperature Range -40~+125℃
|