Message: | Overview
The system aims at the continuous temperature detection of the product obtained from the continuous casting machine. The billets and their surrounding environmental factors such as scale, steam, shielding and other factors, are considered in the scheme design and equipment selection. The accurate detection and real-time transmission of temperature during the billets movement are also considered.
The features
Using Si/Si stack detector, high sensitivity
It is easy to use and has sturdy housing, which meets NEMA-4 standard
Bidirectional RS-485/DP communication (can be networked), supports up to 32 detection sensors at most
With user-defined alarm methods, analog and digital outputs are synchronized
Use protective devices and air cooling devices, can withstand high temperature environment
Accurate measurement of moving targets or targets obscured by dust, smoke and other particles in the atmosphere
Adopt passive cooling apparatus, high cooling efficiency and low maintenance
Use software to remotely set and monitor, analyze and secondary process the data, and optimize occlusion measurement
The parameters
Measurement range:600℃~1400℃
Response time:10msc)
Spectral response:bicolor
Accuracy:±0.75%
Repeatability:±0.3%
Cooling air pressure:>0.5Kpa
Cooling air flow:24L/min
Max.temperature:165℃
Output signal:485 / DP / 4-20mA
Environment standard:NEMA4(IEC529,IP65) |