my account  log out
 

Take you a simple step to distinguish the pros and cons of serum separation gel

Create: 08/27/2020
Expired Date:01/01/2021
Category: Chemical
Message:Serum separation gel, a kind of raw material commonly used in hospital laboratory, is inseparable from many biochemical analyses. It is an inert polymer, insoluble in water, and has high temperature resistance, low temperature resistance, oxidation resistance, and high stability. Some manufacturers such as Desheng's separation glue also have the characteristics of anti-radiation. Therefore, a comparison test must be done before using serum separation gel. The following is a quick, easy and easy-to-operate method to detect triglycerides in the separation gums of various manufacturers, as follows: 1. Apparatus and reagents: automatic biochemical analyzer, triglyceride (TRIG) reagent and calibration solution are special reagents for the instrument, 5ml disposable sterile syringe, Desheng serum separation gel blood collection tube, a certain brand of inferior serum Separation gel blood collection tube, traditional ordinary blood collection tube, 0.9% sodium chloride injection. 2. Method: The traditional ordinary blood collection tube is the control group A, the Desheng serum separation gel collection tube is the control group B, and a certain brand of inferior serum separation gel collection tube is the experimental group C. Each group randomly selects 10 blood collection tubes, each tube Add 5ml 0.9% sodium chloride injection separately, place in 37℃ water bath for 15min, centrifuge at 3000r/min for 10 minutes, measure the above tubes on the automatic biochemical analyzer, record the test results, and compare the results It can be found that TG cannot be detected in the blood collection tubes of group A and B, but different concentrations of TG can be detected in each tube of group C. This method can be used to conduct a comparison test to quickly and accurately identify the quality of the separation gel in the blood collection tube The pros and cons.
City:Wuhan Hubei[CN] 
Location:
 
Sep 29 2021 VTM solution related to COVID-19 testing216
Sep 29 2021 The use of Tris (77-86-1) in different industries215
Sep 16 2021 VTM solution and nucleic acid testing223
Sep 16 2021 characteristics of HEPES buffer239
Sep 14 2021 VTM solution for virus inactivation and lysis219
Sep 14 2021 Types of virus transport medium250
Sep 09 2021 virus sampling tubes and VTM solutions217
Sep 09 2021 4 pH buffers of Desheng used in cosmetics195
Sep 06 2021Potassium EDTA and lithium heparin in blood test246
Sep 06 2021Tris buffer is incompatible with some pH electrodes255

return back

Copyright © toextrade Inc. All rights reserved. Contact us